HARDI Submits Comments to DOE to Prevent Dead Inventory Caused by Proposed Testing Change

June 17, 2024 | 3 minute read

The Department of Energy (DOE) has proposed a new test procedure for central air conditioners and heat pumps (CAC/HP). As part of the proposed test procedure, the DOE also proposed changing how R-410A outdoor condensing units that will be installed after January 1, 2026, are tested and certified to ensure the unit meets minimum energy efficiency standards. Unfortunately, the proposed rule does not specify if existing outdoor condensing units in inventory must also be retested to determine compliance with existing minimum efficiency standards that went into place on January 1, 2023. HARDI has submitted comments encouraging the Outdoor Unit With No Match (OUWNM) test to only apply to outdoor condensing units manufactured for servicing existing equipment. This would align the DOE efficiency requirement with the EPA manufacturing cutoff for split system CAC/HP that use R-410A.

The DOE has proposed this change in response to the EPA Technology Transition Rule that prohibits the installation of full systems using R-410A or other high-GWP refrigerants after January 1, 2026. The EPA requires that any R-410A outdoor condensing unit manufactured after January 1, 2025, must have a label affixed to the unit that says it is “For servicing existing equipment only” and cannot be installed in conjunction with an indoor coil.

DOE ratings for outdoor condensing units are based on testing with an OEM coil to provide a minimum efficiency that the unit can achieve when the outdoor unit and coil are changed together. Because the EPA regulation prohibits changing the indoor coil with the outdoor condensing unit after January 1, 2026, the existing coil may not allow the outdoor condensing unit to meet the minimum efficiency requirement. The DOE created the OUWNM test in 2016 in response to the R-22 phaseout where outdoor units were replaced without changing the indoor coil. The OUWNM test uses a generic coil design and often reduces the efficiency rating of the outdoor condensing unit. This means many base model units might not meet the minimum efficiency requirement when tested as an OUWNM.

If the DOE required all inventory in commerce to be relabeled based on the ratings from the OUWNM test, many base model units would not be legal to install anywhere in the country and create dead inventory. Until the rule is finalized and the DOE’s intent is made clear, the status of existing R-410A outdoor condensing units as replacement components sold after January 1, 2026, is unclear.

HARDI’s full comments to the DOE are available here.

Alex Ayers
Vice President of Government Affairs
Alex is HARDI’s lead lobbyist and regulatory expert, with over a decade of experience in Washington, DC. A former Iowa caucus delegate, he built early roots in grassroots politics. He has lobbied, published, and testified on taxes, energy, environment, agriculture, and economics. His work has been cited by the Wall Street Journal, Forbes, and the Tax Foundation.